Mispa Count Plus

Mispa Count Plus is designed with optimized aperture size which offers better count of RBC and WBC using the principle of electrical impedance. Mispa Count 5 Part differential is based on innovative LBFC (Led-based Flow Cytometry) Technology, which provide accurate and precise count.

Mispa Count Plus, an Intelligent Open-vial 5-part Differential Hematology System. Mispa Count Plus Haematology system increases the laboratory efficiency through its compact design, intuitive operation and fast analysis. Designed with perfection the microfluidic technology improves the performance of the analyser and provides the best fit for any laborator environment. Agappe’s Mispa Count Plus haematology system establishes a new standard in blood count analysis providing remarkable laboratory savings in space, time and operating costs.

PERFORMANCE AT ITS BEST

  • LED based Flow Cytometry & Triple Counting Technology Which Offers Accurate and Precise results
  • 5Part Differential Analyser with 3 Histogram and Scatter Plot for WBC
  • 2D Differential Scatter Plot (Diff Scatter Plot) for 5 Part Differentials
  • 28 Test Parameters
  • Efficient System with throughput of 60 Samples / Hr
  • Low cost of operation and improved laboratory efficiency with Cyanide Free Reagent.
  • Quality results from as little as 15.6 µL of sample & pre diluted 20 µL
  • Patient Memory up to 35000 Samples

Technical Specifications

Technology & Principle

  • Enhanced Electrical Impedance for Cell counting
  • Non-Cyanide method for haemoglobin
  • LED based Flow cytometry for Differential
Sample Volume Whole blood 15.6 µL and pre-diluted 20 µL
Throughput 60 Samples / Hour
Mode Open Vial
Sampling modes Whole blood & Pre-diluted
Counting Modes Differential, CBC + Differential
Storage Capacity 35,000 results memory with Scatter Plot

Physical Characteristics

Screen 8.4-inch LCD touch screen
Dimensions 405 x 270 x 430 mm (H x W x D)
Weight 12 kg
Input Power 100 to 240 VAC, 50 to 60 Hz
Output 24V – 6.25 A
Power Consumption 160 W
Working temperature 18 °C to 32 °C
Relative Humidity 80% max. at 32 °C

Flagging

  • Pathologic flags
  • Reagent alerts
  • Instrument alerts

Interface

Connectivity 5 USB ports, Ethernet – RJ45, RS232
Barcode Connectivity Yes (Hand held barcode reader)
External Printer Yes

Reagents

D5: Mispa Count Plus Diluting the blood
L5: Mispa Count Plus Lysing
C5: Mispa Count Plus Aperture cleaning and wetting
P5: Mispa Count Plu Cleaning the probe

 