Mispa CXL Pro Plus is a compact, fully automated clinical chemistry analyzer with photometric throughput of 240 tests per hour. Mispa CXL Pro Plus has Holographic Concave Flat Field Grating (HCFG) rear spectrophotometry system designed for best reliability and maximum accuracy. On-board washing and cleaning system in Mispa CXL Pro Plus adopting 7 stops 11 steps, ensures minimum carryover and precise result delivery. Mispa CXL Pro Plus is the best in the class with grating, mixing, washing and user-friendly classic features.
SAMPLE/REAGENT PIPETTING MECHANISM

MULTI-FUNCTION SAMPLE & REAGENT CAROUSEL

PROVEN HCFG PHOTOMETRY SYSTEM

TRIPLE SPEED MIXING MECHANISM
System Function
| Description | Fully Automated, discrete, random acess clinical chemistry analyzer Spectrophotometry |
| Measuring principle | Up to 240 tests/hour |
| Photometric throughput | HCFG rear spectrophotometr y |
| Photometric system | End point, Fixed time, Kinetic, Single & Dual reagent chemistries |
| Methodology | Mono & Bi chromatic, Linear & non-linear multipoint calibration |
Optical System
| Light source | Halogen- Tungsten lamp (12V/20W) |
| Monochromator | Grating Photometry (Holographic Concave Flat Field Grating) |
| Wavelength | 340nm, 380nm, 405nm, 450nm, 480nm, 505nm, 546nm, 570nm, 600nm, 660nm, 700nm, 750 or 800nm |
| Linear range | 0 ~ 3.3 Abs |
| Detector | Photodiode array |
Reagent/Sample Handling
| Reagent/Sample tray | Multi-functional reagent and sample carousel |
| Reagent/Sample position | Up to 80 positions |
| Sample cuvette specification | Standard cup, original blood tube, multi-specification tube (10~13) x (75~100) mm |
| Sample reagent probe | Digital liquid level detection and vertical collision protection |
| Sample dilution | Pre & Post dilution facility |
| Reagent volume | 10~300 µl |
| Sample volume | 2~35 µl |
| Dilution vessel | UV plastic semi permanent cuvette |
| Reagent bottle volume | 20 & 70 ml |
Reaction System
| Reaction cuvette | 56 positions optical plastic cup |
| Reaction volume | 100~360 µl |
| Reaction temperature | 37±0.1°C |
| Reaction disk constant temperature | Thermostat air bath |
| Mixing system | Teflon coated stirrer with triple speed mixing mechanism |
| Laundry system | Efficient system adopting 7 stops, 11 steps |
Operation Unit
| PC operation system | Windows 7 or Windows 10 |
| PC configuration | CPU > 2.9 Ghz (dual core processor); RAM > 4 GB; Harddisk ≥ 160 GB |
| Analysis control | Graphical operating software |
| Report printing | Supports user-defined mode, QC and state information etc |
| System connection | TCP/IP network connection, standard RJ-45 |
Calibration & Quality Control
| Calibration method | Linear (One-point, two-point and multi-point), Logit-Log 4P, Logit-Log 5P, Spline, Exponential, Polynomial |
| Quality control method | Real-time, daily, monthly & QC chart | Visual QC assessment | QC histroy checking QC error analysis |
| Parabola control rules | Westgard multi-rule, L-J char |
Working Conditions
| Power supply | 100~240 VAC | 50/60Hz | Power 600VA |
| Ambient temperature | 15°C~25°C |
| Relative humidity | 40% ~ 85% |
| Atmospheric pressure | 70-106kPa |
| Water consumption | 4L/hour |
| Dimensions (LxWxH) | 744x703x530 mm |
| Weight | Approx. 100 kg |